Stent Graft Application to Expand Possibilities for Aortic Treatment
• The Atlas Aortic Stent Graft represents a significant leap forward inaortic lesions.
• Designed with cutting-edge materials and engineering, Atlas Aortic Stent Graft ensuresoptimal support and flexibility for aortic interventions.
• Precision-engineered deployment system.
Hybrid Technology to Help Support Improved Patient Outcomes
• With a wide range of sizes, diameters and tapers to customise to the needs of each patient.
• Design: The main body stent is high conformability due to varying stent height and is kink resistant.
• A multiple tapered configurations that supports the treatment of dissectionsThe proximal seal has a novel proximal stent design and a mini spring that enhances wall apposition.
Every Aspect of the Atlas Aortic Stent-Graft System is Engineered for Performance.
• Two levels of confident fixation.
• Lock stent technology works to prevent modular disconnection.
• Unique leave-behind sheath to simplify the procedure.
AORTIC STENT GRAFTS ARE INDICATED FOR THE TREATMENT OF AORTIC ANEURYSMS:
•Less invasive than open surgery
•Shorter recovery time
•Lower risk of complications
•Types of aortic stent grafts
AORTIC STENT GRAFTS ARE INDICATED FOR THE TREATMENT OF AORTIC ANEURYSMS:
•Large enough to rupture
•Growing in size
•Causing symptoms
•Complications of aortic stent grafts
General Product Specifications
Specification | Detail / Value |
Product Name | Atlas Aortic Stent Graft |
Intended Use | Endovascular repair of thoracic or abdominal aortic aneurysms (TAA/AAA), aortic dissections, or traumatic injuries |
Design | Balloon-expandable or self-expanding covered stent with ePTFE graft material |
Material | Base scaffold: Nitinol alloy Graft covering: ePTFE / PTFE |
Deployment Mechanism | Self-expandable: sheath-based release |
Delivery System | Typically 14–24F introducer sheath compatibility, depending on final diameter |
Radiopacity | Radiopaque markers at proximal and distal ends for precise positioning |
Sterility | Sterile (Ethylene Oxide) |
Single Use | Yes |
Shelf Life | ~3–5 years (in sealed packaging at 15–25 °C) |
MR Compatibility | MR Conditional (verify with labeling) |
Clinical Indications | Infrarenal AAA, TAA, chronic aortic dissection, traumatic aortic tears, side-branch occlusion, etc. |
Contraindications | Unsuitable neck angles, severe vessel calcification or tortuosity, known nickel allergies (if nitinol) |
Atlas Aortic Stent Graft
Diameter (mm) | Length (mm) | Sheath Rec. | Product Code | Notes |
20 | 80 | 14F | ATLS-SG-20x80-SE | Smaller diameter, short coverage |
20 | 100 | 14F | ATLS-SG-20x100-SE | |
20 | 120 | 14F | ATLS-SG-20x120-SE | |
22 | 100 | 16F | ATLS-SG-22x100-SE | For moderate aortic diameters |
22 | 140 | 16F | ATLS-SG-22x140-SE | Extended coverage |
24 | 120 | 16F | ATLS-SG-24x120-SE | Common AAA dimension |
24 | 160 | 16F | ATLS-SG-24x160-SE | Extended graft for fusiform aneurysms |
26 | 120 | 18F | ATLS-SG-26x120-SE | Larger diameter, moderate length |
26 | 160 | 18F | ATLS-SG-26x160-SE | |
28 | 140 | 20F | ATLS-SG-28x140-SE | |
28 | 180 | 20F | ATLS-SG-28x180-SE | For more extensive aneurysms |
30 | 140 | 20F | ATLS-SG-30x140-SE | |
30 | 180 | 20F | ATLS-SG-30x180-SE | |
32 | 140 | 22F | ATLS-SG-32x140-SE | Large diameter for TAA or big AAA |
32 | 180 | 22F | ATLS-SG-32x180-SE | |
34 | 160 | 22F | ATLS-SG-34x160-SE | |
36 | 160 | 22F | ATLS-SG-36x160-SE | |
38 | 180 | 24F | ATLS-SG-38x180-SE | Extremely large aorta |
40 | 200 | 24F | ATLS-SG-40x200-SE | Maximum coverage for giant aneurysm or extended segment |