MultiBEAM Inferior Vena Cava (IVC) Filter

The MultiBEAM Inferior Vena Cava (IVC) Filter, offered by Invamed—a global medical device manufacturer—is designed to capture and retain thromboembolic fragments traveling within the venous system, thereby reducing the risk of pulmonary embolism (PE). Featuring a self-expanding metallic framework, MultiBEAM provides robust fixation in the IVC while facilitating high patency and stable clot containment.

Self-Expanding Nitinol Struts
Engineered from a biocompatible alloy for secure anchoring, even under shifting venous pressures.

Multi-Spoke or “Beam” Design
Creates multiple capture zones that efficiently trap emboli without significantly restricting blood flow, sustaining venous return.

Retrievable/Optional Permanent
Certain models allow retrieval within a designated window, while others function as permanent PE prophylaxis solutions—offering clinicians flexibility in management.

Reduced Migration & Tilt
Precisely balanced struts help prevent filter migration or tilting, enhancing performance consistency over time.

Wide Application Scope
Indicated for patients at elevated PE risk due to venous thromboembolism (VTE), inadequate response to anticoagulants, or temporary contraindications to anticoagulation therapy.

Contraindications
Excessively narrow or tortuous IVC diameter preventing secure seating, active infection at insertion site, or patient-specific anatomical constraints.

MultiBEAM Inferior Vena Cava (IVC) Filter

Product Specifications

Specification Detail / Value
Product Name MultiBEAM Inferior Vena Cava (IVC) Filter
Intended Use Prevention of pulmonary embolism by capturing clots traveling from lower extremity or pelvic veins
Filter Design Self-expanding metal struts (Nitinol or stainless steel) arranged in a multi-beam pattern
Deployment Mechanism Over-the-wire or sheath-based insertion, typically via femoral or jugular access
Retrieval Option Some models are optionally retrievable within a specific timeframe (check product line)
Filter Diameter Range Suited for IVC diameters ~20–30 mm (varies by product code)
Radiopaque Markers Distal apex or anchor tips for fluoroscopic identification
MR Compatibility MR Conditional (verify labeling)
Sterility Sterile, Single Use
Shelf Life ~3–5 years if stored at 15–25 °C in sealed packaging
Clinical Indications Patients at risk of pulmonary embolism (PE), especially with contraindications to anticoagulation
Contraindications Severe IVC anatomical anomalies, high-level occlusion, known allergy to device materials

Ordering & Size Matrix

IVC Diameter Suitability (mm) Filter Apex to Anchor (mm) Retrieval Window (days) Product Code Notes
< 24 26 30 MBI-<24-40-30 Smaller IVC or narrow diameters
< 24 26 90 MBI-<24-50-90 Extended retrieval time
20–28 33 30 MBI-20-28-50-30 Common range for standard IVC diameters
20–28 33 90 MBI-20-28-60-90 Longer apex distance + extended retrieval
28–30 33 30 MBI-28-30-60-30 For larger IVC diameter, shorter retrieval
28–30 33 90 MBI-28-30-70-90 Largest apex span + extended retrieval