Rotational Pharmacomechanical Thrombectomy
•Venturi Effect Mechanism: As the active tip spins within the vessel lumen, a hydrodynamic vortex forms, enabling targeted fragmentation and aspiration of the thrombus.
•Drug Infusion Port: Concurrent infusion of anti-thrombolytic agents ensures cohesive mixing with the thrombus, expediting clot dissolution and clearance.
Active Tip with Coil & Sinusoidal Wave
•Coil Design: The sinusoidal wave geometry, visible from the distal tip to proximal region, efficiently engages and fragments clot.
•Preventing Distal Embolism: The rotational vortex action, combined with controlled drug release, helps retain clot particles in proximity for prompt removal, reducing the risk of distal migration.
Over-the-Wire (OTW) Catheter System
•0.035” Guidewire Compatibility: Simplifies wire management in complex anatomies (including tortuous or large-diameter vessels).
•Catheter Lengths: With 90 cm and 110 cm functional lengths, and 120 cm or 135 cm profiles, the system accommodates an array of procedural approaches.
Multiple Catheter Profiles & Radiopacity
•5.0F to 8.0F: Offers suitable sizing for broad vessel diameters in the peripheral venous circulation, pulmonary artery, or IVC.
•Radiopaque: The braided shaft is visible under fluoroscopy from distal tip to proximal segment, aiding real-time device positioning.
PTFE Inner Lining
•Low-Friction Catheter Lumen: Streamlines guidewire passage and drug infusion, helping avoid clot or tissue adherence to the catheter walls.
•Reduced Shear Stress: Minimizes friction on vessel endothelium, supporting safer navigation in high-stakes procedures.
Product Specifications
Specification | Detail / Value |
Product Name | Mantis CURVE OTW Rotational Pharmacomechanical Thrombectomy System |
Intended Use | Combined mechanical disruption + lytic infusion for acute/subacute thrombosis in peripheral or venous systems |
Catheter Design | Over-the-wire shaft with curved rotational tip for enhanced clot contact, integrated infusion port |
Rotational Speed Range | ~40k–80k rpm (verify final) |
Infusion Mechanism | Side port or multi-hole segment for tPA or lytic agent delivery |
Outer Diameter (F) | ~5–7F, depending on model |
Working Length | ~80–120 cm (varies by product code) |
Guidewire Compatibility | Typically 0.035” (OTW approach) |
Sterility | Sterile, Single Use |
Shelf Life | ~2–3 years at 15–25 °C in sealed packaging |
Clinical Indications | Deep venous thrombosis (DVT), acute peripheral arterial occlusions, possibly for pulmonary thrombosis (per label) |
Contraindications | Extremely tortuous vessels, heavy calcification, or known device material allergies |
Ordering & Size Matrix
Outer Diameter (F) | Working Length (cm) | Curve Tip Configuration | Product Code | Notes |
5F | 80 | Moderate Curve | MNT-CV-5F-80-MC | Smaller lumen, shorter approach |
5F | 100 | Deep Curve | MNT-CV-5F-100-DC | Extended shaft, deeper curve for better clot contact |
6F | 80 | Moderate Curve | MNT-CV-6F-80-MC | Common size for peripheral thrombectomy |
6F | 120 | Deep Curve | MNT-CV-6F-120-DC | Extended length with advanced curve tip |
7F | 100 | Moderate Curve | MNT-CV-7F-100-MC | Larger lumen for heavier clot burden |
7F | 120 | Deep Curve | MNT-CV-7F-120-DC | Max length, enhanced curve for extensive occlusions |